@@ -153,7 +153,7 @@ class OfficeLANAdder(NetworkNodeAdder, identifier="office_lan"):
# Create a core switch if more than one edge switch is needed
if num_of_switches > 1:
core_switch = Switch(hostname=f"switch_core_{config.lan_name}", start_up_duration=0)
core_switch = Switch.from_config(config = {"type":"switch","hostname":f"switch_core_{config.lan_name}", "start_up_duration": 0 })
core_switch.power_on()
network.add_node(core_switch)
core_switch_port = 1
@@ -164,7 +164,8 @@ class OfficeLANAdder(NetworkNodeAdder, identifier="office_lan"):
# Optionally include a router in the LAN
if config.include_router:
default_gateway = IPv4Address(f"192.168.{config.subnet_base}.1")
router = Router(hostname=f"router_{config.lan_name}", start_up_duration=0)
# router = Router(hostname=f"router_{config.lan_name}", start_up_duration=0)
router = Router.from_config(config={"hostname":f"router_{config.lan_name}", "type": "router", "start_up_duration": 0})
router.power_on()
router.acl.add_rule(
action=ACLAction.PERMIT, src_port=PORT_LOOKUP["ARP"], dst_port=PORT_LOOKUP["ARP"], position=22
@@ -177,7 +178,7 @@ class OfficeLANAdder(NetworkNodeAdder, identifier="office_lan"):
# Initialise the first edge switch and connect to the router or core switch
switch_port = 0
switch_n = 1
switch = Switch(hostname=f"switch_edge_{switch_n}_{config.lan_name}", start_up_duration=0)
switch = Switch.from_config(config={"type": "switch","hostname":f"switch_edge_{switch_n}_{config.lan_name}", "start_up_duration":0})
switch.power_on()
network.add_node(switch)
if num_of_switches > 1:
@@ -195,7 +196,7 @@ class OfficeLANAdder(NetworkNodeAdder, identifier="office_lan"):
if switch_port == effective_network_interface:
switch_n += 1
switch_port = 0
switch = Switch(hostname=f"switch_edge_{switch_n}_{config.lan_name}", start_up_duration=0)
switch = Switch.from_config(config={"type": "switch","hostname":f"switch_edge_{switch_n}_{config.lan_name}", "start_up_duration":0})
switch.power_on()
network.add_node(switch)
# Connect the new switch to the router or core switch
@@ -212,13 +213,13 @@ class OfficeLANAdder(NetworkNodeAdder, identifier="office_lan"):
)
# Create and add a PC to the network
pc = Computer(
hostname=f"pc_{i}_{config.lan_name}",
ip_address=f"192.168.{config.subnet_base}.{i+config.pcs_ip_block_start-1}",
subnet_mask="255.255.255.0",
default_gateway=default_gateway,
start_up_duration=0,
)
pc_cfg = {"type": "computer",
"hostname": f"pc_{i}_{config.lan_name}",
"ip_address": f"192.168.{config.subnet_base}.{i+config.pcs_ip_block_start-1}",
"default_gateway": "192.168.10.1",
"start_up_duration": 0,
}
pc = Computer.from_config(config = pc_cfg)
pc.power_on()
network.add_node(pc)

View File

@@ -1979,7 +1979,7 @@ class Node(SimComponent, ABC):
else:
if self.operating_state == NodeOperatingState.SHUTTING_DOWN:
self.operating_state = NodeOperatingState.OFF
self.sys_log.info(f"{self.hostname}: Turned off")
self.sys_log.info(f"{self.config.hostname}: Turned off")
self._shut_down_actions()
# if resetting turn back on

View File

@@ -129,7 +129,7 @@ class Switch(NetworkNode, identifier="switch"):
if markdown:
table.set_style(MARKDOWN)
table.align = "l"
table.title = f"{self.hostname} Switch Ports"
table.title = f"{self.config.hostname} Switch Ports"
for port_num, port in self.network_interface.items():
table.add_row([port_num, port.mac_address, port.speed, "Enabled" if port.enabled else "Disabled"])
print(table)

View File

@@ -128,32 +128,34 @@ def arcd_uc2_network() -> Network:
network = Network()
# Router 1
router_1 = Router(hostname="router_1", num_ports=5, start_up_duration=0)
router_1 = Router.from_config(config={"type":"router", "hostname":"router_1", "num_ports":5, "start_up_duration":0})
router_1.power_on()
router_1.configure_port(port=1, ip_address="192.168.1.1", subnet_mask="255.255.255.0")
router_1.configure_port(port=2, ip_address="192.168.10.1", subnet_mask="255.255.255.0")
# Switch 1
switch_1 = Switch(hostname="switch_1", num_ports=8, start_up_duration=0)
switch_1 = Switch.from_config(config={"type":"switch", "hostname":"switch_1", "num_ports":8, "start_up_duration":0})
switch_1.power_on()
network.connect(endpoint_a=router_1.network_interface[1], endpoint_b=switch_1.network_interface[8])
router_1.enable_port(1)
# Switch 2
switch_2 = Switch(hostname="switch_2", num_ports=8, start_up_duration=0)
switch_2 = Switch.from_config(config={"type":"switch", "hostname":"switch_2", "num_ports":8, "start_up_duration":0})
switch_2.power_on()
network.connect(endpoint_a=router_1.network_interface[2], endpoint_b=switch_2.network_interface[8])
router_1.enable_port(2)
# Client 1
client_1 = Computer(
hostname="client_1",
ip_address="192.168.10.21",
subnet_mask="255.255.255.0",
default_gateway="192.168.10.1",
dns_server=IPv4Address("192.168.1.10"),
start_up_duration=0,
)
client_1_cfg = {"type": "computer",
"hostname": "client_1",
"ip_address": "192.168.10.21",
"subnet_mask": "255.255.255.0",
"default_gateway": "192.168.10.1",
"dns_server": IPv4Address("192.168.1.10"),
"start_up_duration": 0,
}
client_1: Computer = Computer.from_config(config = client_1_cfg)
client_1.power_on()
network.connect(endpoint_b=client_1.network_interface[1], endpoint_a=switch_2.network_interface[1])
client_1.software_manager.install(DatabaseClient)
@@ -172,14 +174,17 @@ def arcd_uc2_network() -> Network:
)
# Client 2
client_2 = Computer(
hostname="client_2",
ip_address="192.168.10.22",
subnet_mask="255.255.255.0",
default_gateway="192.168.10.1",
dns_server=IPv4Address("192.168.1.10"),
start_up_duration=0,
)
client_2_cfg = {"type": "computer",
"hostname": "client_2",
"ip_address": "192.168.10.22",
"subnet_mask": "255.255.255.0",
"default_gateway": "192.168.10.1",
"dns_server": IPv4Address("192.168.1.10"),
"start_up_duration": 0,
}
client_2: Computer = Computer.from_config(config = client_2_cfg)
client_2.power_on()
client_2.software_manager.install(DatabaseClient)
db_client_2 = client_2.software_manager.software.get("DatabaseClient")
@@ -193,27 +198,34 @@ def arcd_uc2_network() -> Network:
)
# Domain Controller
domain_controller = Server(
hostname="domain_controller",
ip_address="192.168.1.10",
subnet_mask="255.255.255.0",
default_gateway="192.168.1.1",
start_up_duration=0,
)
domain_controller_cfg = {"type": "server",
"hostname": "domain_controller",
"ip_address": "192.168.1.10",
"subnet_mask": "255.255.255.0",
"default_gateway": "192.168.1.1",
"start_up_duration": 0
}
domain_controller = Server.from_config(config=domain_controller_cfg)
domain_controller.power_on()
domain_controller.software_manager.install(DNSServer)
network.connect(endpoint_b=domain_controller.network_interface[1], endpoint_a=switch_1.network_interface[1])
# Database Server
database_server = Server(
hostname="database_server",
ip_address="192.168.1.14",
subnet_mask="255.255.255.0",
default_gateway="192.168.1.1",
dns_server=IPv4Address("192.168.1.10"),
start_up_duration=0,
)
database_server_cfg = {"type": "server",
"hostname": "database_server",
"ip_address": "192.168.1.14",
"subnet_mask": "255.255.255.0",
"default_gateway": "192.168.1.1",
"dns_server": IPv4Address("192.168.1.10"),
"start_up_duration": 0
}
database_server = Server.from_config(config=database_server_cfg)
database_server.power_on()
network.connect(endpoint_b=database_server.network_interface[1], endpoint_a=switch_1.network_interface[3])
@@ -223,14 +235,18 @@ def arcd_uc2_network() -> Network:
database_service.configure_backup(backup_server=IPv4Address("192.168.1.16"))
# Web Server
web_server = Server(
hostname="web_server",
ip_address="192.168.1.12",
subnet_mask="255.255.255.0",
default_gateway="192.168.1.1",
dns_server=IPv4Address("192.168.1.10"),
start_up_duration=0,
)
web_server_cfg = {"type": "server",
"hostname": "web_server",
"ip_address": "192.168.1.11",
"subnet_mask": "255.255.255.0",
"default_gateway": "192.168.1.1",
"dns_server": IPv4Address("192.168.1.10"),
"start_up_duration": 0
}
web_server = Server.from_config(config=web_server_cfg)
web_server.power_on()
web_server.software_manager.install(DatabaseClient)
@@ -247,27 +263,30 @@ def arcd_uc2_network() -> Network:
dns_server_service.dns_register("arcd.com", web_server.network_interface[1].ip_address)
# Backup Server
backup_server = Server(
hostname="backup_server",
ip_address="192.168.1.16",
subnet_mask="255.255.255.0",
default_gateway="192.168.1.1",
dns_server=IPv4Address("192.168.1.10"),
start_up_duration=0,
)
backup_server_cfg = {"type": "server",
"hostname": "backup_server",
"ip_address": "192.168.1.16",
"subnet_mask": "255.255.255.0",
"default_gateway": "192.168.1.1",
"dns_server": IPv4Address("192.168.1.10"),
"start_up_duration": 0
}
backup_server: Server = Server.from_config(config=backup_server_cfg)
backup_server.power_on()
backup_server.software_manager.install(FTPServer)
network.connect(endpoint_b=backup_server.network_interface[1], endpoint_a=switch_1.network_interface[4])
# Security Suite
security_suite = Server(
hostname="security_suite",
ip_address="192.168.1.110",
subnet_mask="255.255.255.0",
default_gateway="192.168.1.1",
dns_server=IPv4Address("192.168.1.10"),
start_up_duration=0,
)
security_suite_cfg = {"type": "server",
"hostname": "backup_server",
"ip_address": "192.168.1.110",
"subnet_mask": "255.255.255.0",
"default_gateway": "192.168.1.1",
"dns_server": IPv4Address("192.168.1.10"),
"start_up_duration": 0
}
security_suite: Server = Server.from_config(config=security_suite_cfg)
security_suite.power_on()
network.connect(endpoint_b=security_suite.network_interface[1], endpoint_a=switch_1.network_interface[7])
security_suite.connect_nic(NIC(ip_address="192.168.10.110", subnet_mask="255.255.255.0"))